| Force New Analysis | This tells SIMPLIS to ignore any state information that it may have stored and which could be used to speed up the run. For example, any stored snapshots (see above) will not be used if this is selected. | 
            
              | No Forced Output Data | If checked, SIMPLIS will not force a data point before and after
                every switching instant.
                
                
Under most circumstances, this option should remain turned
                OFF. For very long simulations that generate extremely large
                data sets, the waveform viewer may be slow responding to user
                commands. In such cases, turning ON the
                NO_FORCED_DATA option will reduce the number of
                simulation data points displayed in the waveform viewer during
                each switching cycle. For long simulations that involve many
                switching instants in one switching cycle this reduction can be
                significant. Enabling this option in no way degrades the
                accuracy of the SIMPLIS solution, but it can potentially reduce
                the fidelity of the displayed waveforms within each switching
                cycle. |