» SIMPLIS DVM Test Report Overview

General
Schematic DVM_PFC_Continuous_Conduction_Mode.sxsch
Testplan dvm_advanced.testplan
Original Testplan Filename dvm_builtin-acdc_1in_1out.testplan
Date / Time 2015-12-10 6:17 PM
Report Directory ac_dc_built_in
Log File dvm_advanced.log
# of Tests Run 17 of 17 (17 of 17 Run, 10 Passed, 7 Failed, 0 Ran with Warnings, 0 Skipped)
Total Time 19m 32s
Design Specifications
Circuit Name DVM_PFC_Continuous_Conduction_Mode
Description 200W Continuous Conduction Mode PFC
Input 1 (Low Line) 115 VRMS Nominal (85 VRMS to 132 VRMS)
Input 1 (High Line) 230 VRMS Nominal (170 VRMS to 265 VRMS)
Output 1 400 V (±5%) @ 500m A
Low Frequency 50Hz
High Frequency 60Hz
Switching Frequency 100kHz
Excel-compatible Results
Scalar Results dvm_advanced_table_scalars.txt
Spec Results dvm_advanced_table_specs.txt
Statistic Results dvm_advanced_table_statistics.txt
Statistic Specs dvm_advanced_table_statspecs.txt
Test 1 of 17top ▲
Test Label Transient|FindACSteadyState|LL_Nominal|F_High|Enabled|Light Load
Simulator simplis
Test Report Transient\FindACSteadyState\LL_Nominal\F_High\Enabled\LightLoad\report.txt.html
Status PASS
Test Time 1m 56s
Test 2 of 17top ▲
Test Label Transient|FindACSteadyState|HL_Maximum|F_Low|Enabled|100% Load
Simulator simplis
Test Report Transient\FindACSteadyState\HL_Maximum\F_Low\Enabled\100%Load\report.txt.html
Status PASS
Test Time 1m 32s
Test 3 of 17top ▲
Test Label Transient|FindACSteadyState|HL_Maximum|F_Low|Disabled|Light Load
Simulator simplis
Test Report Transient\FindACSteadyState\HL_Maximum\F_Low\Disabled\LightLoad\report.txt.html
Status PASS
Test Time 12s
Test 4 of 17top ▲
Test Label Transient|ACSteadyState|HL_Maximum|F_Low|Light Load
Simulator simplis
Test Report Transient\ACSteadyState\HL_Maximum\F_Low\LightLoad\report.txt.html
Status FAIL
Test Time 30s
Test 5 of 17top ▲
Test Label Transient|ACSteadyState|LL_Nominal|F_High|50% Load
Simulator simplis
Test Report Transient\ACSteadyState\LL_Nominal\F_High\50%Load\report.txt.html
Status FAIL
Test Time 30s
Test 6 of 17top ▲
Test Label Transient|ControlStartup|HL_Maximum|F_Low|Light Load
Simulator simplis
Test Report Transient\ControlStartup\HL_Maximum\F_Low\LightLoad\report.txt.html
Status PASS
Test Time 1m 32s
Test 7 of 17top ▲
Test Label Transient|ControlStartup|LL_Maximum|F_High|100% Load
Simulator simplis
Test Report Transient\ControlStartup\LL_Maximum\F_High\100%Load\report.txt.html
Status PASS
Test Time 1m 44s
Test 8 of 17top ▲
Test Label Transient|LineStartup|LL_Maximum|F_High|Light Load
Simulator simplis
Test Report Transient\LineStartup\LL_Maximum\F_High\LightLoad\report.txt.html
Status FAIL
Test Time 1m 39s
Test 9 of 17top ▲
Test Label Transient|LineStartup|HL_Maximum|F_Low|100% Load
Simulator simplis
Test Report Transient\LineStartup\HL_Maximum\F_Low\100%Load\report.txt.html
Status FAIL
Test Time 1m 11s
Test 10 of 17top ▲
Test Label Transient|LineDropout|HL_Nominal|F_Low|1Cycles|100% Load
Simulator simplis
Test Report Transient\LineDropout\HL_Nominal\F_Low\1Cycles\100%Load\report.txt.html
Status FAIL
Test Time 47s
Test 11 of 17top ▲
Test Label Transient|LineDropout|HL_Nominal|F_High|1Cycles|100% Load
Simulator simplis
Test Report Transient\LineDropout\HL_Nominal\F_High\1Cycles\100%Load\report.txt.html
Status FAIL
Test Time 41s
Test 12 of 17top ▲
Test Label Transient|LineSag|HL_Nominal_to_HL_Sag|F_Low|50% Load
Simulator simplis
Test Report Transient\LineSag\HL_Nominal_to_HL_Sag\F_Low\50%Load\report.txt.html
Status PASS
Test Time 1m 24s
Test 13 of 17top ▲
Test Label Transient|LineSag|LL_Nominal_to_LL_Sag|F_High|100% Load
Simulator simplis
Test Report Transient\LineSag\LL_Nominal_to_LL_Sag\F_High\100%Load\report.txt.html
Status FAIL
Test Time 1m 17s
Test 14 of 17top ▲
Test Label Transient|LineSurge|HL_Maximum_to_HL_Surge|F_High|Light Load
Simulator simplis
Test Report Transient\LineSurge\HL_Maximum_to_HL_Surge\F_High\LightLoad\report.txt.html
Status PASS
Test Time 40s
Test 15 of 17top ▲
Test Label Transient|LineSurge|HL_Maximum_to_HL_Surge|F_Low|100% Load
Simulator simplis
Test Report Transient\LineSurge\HL_Maximum_to_HL_Surge\F_Low\100%Load\report.txt.html
Status PASS
Test Time 1m 14s
Test 16 of 17top ▲
Test Label Transient|LoadTrAC|LL_Nominal|F_High|Light Load to 50% Load to Light Load
Simulator simplis
Test Report Transient\LoadTrAC\LL_Nominal\F_High\LightLoad to 50% Load to Light Load\report.txt.html
Status PASS
Test Time 1m 11s
Test 17 of 17top ▲
Test Label Transient|LoadTrAC|HL_Nominal|F_Low|Light Load to 100% Load to Light Load
Simulator simplis
Test Report Transient\LoadTrAC\HL_Nominal\F_Low\LightLoad to 100% Load to Light Load\report.txt.html
Status PASS
Test Time 1m 18s