back to overview ▲

» DVM Test Report: Transient|FindACSteadyState|HL_Maximum|F_Low|Disabled|Light Load

Test Details
Schematic DVM_PFC_Continuous_Conduction_Mode.sxsch
Test Transient|FindACSteadyState|HL_Maximum|F_Low|Disabled|Light Load
Date / Time 12/10/2015 6:21 PM
Report Directory ac_dc_built_in\Transient\FindACSteadyState\HL_Maximum\F_Low\Disabled\LightLoad
Log File report.txt
Screenshot schematic.png
Status PASS
Simulator simplis
Deck input.deck
Init input.deck.init
Measured Scalar Values
Frequency(Line) 50
ILine
MIN
-724.567m
MAX
724.567m
IPFCOutput
MIN
90.6061m
MAX
91.6064m
VLine
MIN
-374.315
MAX
374.315
RMS
265
VPFCOutput
MIN
362.425
MAX
366.426
VPFCOutput %_diff_last_2_linecycles 0.0000000000140108%
VPFCOutput At Simulation Start Time
AVG
364.33
VPFCOutput Last LineCycle
AVG
364.33
VPFCOutput Previous LineCycle
AVG
364.33
Measured Spec Values
AC_Settling(PFCOutput) PASS: Voltage across PFCOutput has settled to (140.108f) % and is less than or equal to Max Settling Spec of (10m) %
Max_VPFCOutput PASS: Max. Output1 Voltage (366.426) is less than or equal to Max. Output1 Voltage Spec (420)
PFCOutput
VPFCOutput
IPFCOutput
SXGPH File simplis_tran3_47.sxgph
Line
VLine
ILine
SXGPH File simplis_tran3_52.sxgph
Other SXGPH Files
AC#tran simplis_tran3_41.sxgph